PRODUCT DATA SHEET
Polymer: Recycled high‐density polyethylene (R‑HDPE)
Source: Bottles, containers, industrial scrap
Color: White, black or colored
Additives: Stabilizers, pigments, antioxidants
Available Colors:
- Malaboro red
- Dark Blue
- Mid Blue
- Light Blue
- Mid Green
- Orange
- White
- Dark Green
| Property | Typical Value | Test Method |
|---|---|---|
| Density | 0.94 – 0.96 g/cm³ | ISO 1183 |
| Melt Flow Rate (190°C/2.16kg) | 4 – 8 g/10 min | ISO 1133 |
| Flexural Modulus | 550 – 750 MPa | ISO 178 |
| Elongation at Break | > 200% | ISO 527 |
| Charpy Impact Strength, notched (23°C) | 35 – 55 kJ/m² | ISO 179/1eA |
- Data should not be used for specification work.
- Measured on injection moulded specimens acc. to ISO 1873-2.
- Measured on injection moulded specimens, conditioned at 23°C and 50% Rel. Hum.
Easy to process with standard injection moulding machines
Following parameters should be used as guidelines:
- • Drying: not needed (PE is non-polar, low moisture absorption)
- • Extrusion / injection: ~180 – 240 °C (depending on grade)
- • Screw design: moderate back pressure
- • Avoid overheating / residence time for thermal stability
- • Use stabilizers (antioxidants) during compounding
- • If blending with virgin, pre‑dry and pre‑mixing beneficial
- • Store dry, cool, away from UV
- • Use sealed containers / bags
- • Prevent contamination (dust, other polymers)
- • Avoid stacking heavy loads that crush pellets
Processing fumes are mild (mostly hydrocarbon vapors)
Use ventilation, PPE
Ingestion, inhalation of pellets or dust to be avoided
Scrap recycling is preferred; disposal per local regulations, for more information contact your PAFT representative.
Very good potential for mechanical recycling
With each cycle, molecular weight falls, property deterioration
Compatibility issues with other polyolefins (poor miscibility)
Sorting, washing, decontamination critical
Closed-loop and open-loop recycling common
The following related documents are available on request, and represent various aspects on the usability, safety, recovery and disposal of the product.
- • Safety Information Sheet
- • Statement on chemicals, regulations and standards
- • Statement on compliance to food contact regulations
The product(s) mentioned herein are not intended to be used for medical, pharmaceutical or healthcare applications and we do not support their use for such applications.
To the best of our knowledge, the information contained herein is accurate and reliable as of the date of publication, however we do not assume any liability whatsoever for the accuracy and completeness of such information.
PAFT makes no warranties which extend beyond the description contained herein. Nothing herein shall constitute any warranty of merchantability or fitness for a particular purpose.
It is the customer's responsibility to inspect and test our products in order to satisfy itself as to the suitability of the products for the customer's particular purpose.
The customer is responsible for the appropriate, safe and legal use, processing and handling of our products.
No liability can be accepted in respect of the use of PAFT products in conjunction with other materials. The information contained herein relates exclusively to our products when not used in conjunction with any third-party materials.